Start | |
---|---|
End | |
Type | Planned |
Status | Completed |
Outage Duration | 0 |
Changing to dedicated fault domain for iSCSI replication traffic. No downtime expected.
No need to redo all the replications right away. Needed to delete old HBAs that were no longer used.
Note made on 2019-10-17 05:40:02Due to how port mappings are saved to replication configurations, each replication will need to be torn down and recreated to accurately reflect iSCSI ports in use. Maintenance end time will be extended until replications are re-created.
Note made on 2019-10-17 01:15:50Connectivity confirmed and traffic is passing on REPL FD. Removing front end fault domains from replication now.
Note made on 2019-10-17 00:02:54Add new "REPL FD" to remote iSCSI connection configuration.
Note made on 2019-10-16 23:56:51Update of MTU successful.
Note made on 2019-10-16 23:54:00Fix MTU on existing fault domain before proceeding.
SA2 Domain 50 MTU 1500 to 9000
Note made on 2019-10-16 23:51:51